Command Control
FQ2-S/CH User’s Manual
for Communications Settings
245
5
Appendices
Load All Setting Data
This command loads all setting data (all scene data, system data, calibration group data) for the Sensor saved
as a backup file from the SD card inserted in the Touch Finder.
The source for backup files is the following fixed directory on the SD card.
\Sensor name\BKD
The file name is not case sensitive. The file name extension can be omitted.
After loading the all data with this command, be sure to restart the Vision Sensor to enable the data that was loaded.
Command (PLC to Vision Sensor)
*1 Loads the files named SensorAll_***.bkd saved on the SD card. (***: Specified file number)
Response (Vision Sensor to PLC)
First word of com-
mand area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0101 0000 0000 0000 Command code
+3 0000 0000 0110 0000
+4 0000 0000 0000 0000 EtherNet/IP,
PROFINET
File number to load
(0 to 999)*1
PLC link
File name to load
64 characters max.
The file name exten-
sion (.bkd) can be
omitted.
+5 0000 0000 0000 0000
+6 0000 0000 0000 0000
---
: ::::
+37 0000 0000 0000 0000
First word of
response area
Bits Contents
12 to 15 8 to 11 4 to 7 0 to 3
+2 0101 0000 0000 0000 Command code
Response target command codes
+3 0000 0000 0110 0000
+4 0000 0000 0000 0000 Response code
Command execution result
0: OK, FFFFFFFF: NG
+5 0000 0000 0000 0000
Important
FQ2-S_CH_comm.book 245 ペー 01年626 木日 前1時4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FQ2-S Series and is the answer not in the manual?

Omron FQ2-S Series Specifications

General IconGeneral
BrandOmron
ModelFQ2-S Series
CategorySecurity Camera
LanguageEnglish

Related product manuals