Command Control
268
FQ2-S/CH User’s Manual
for Communications Settings
Execute Measurement
This command executes one measurement.
If data output is not set, only the measurement is performed.
If data output is set, the measurement is performed and the result is returned as response data.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Set the data output to output measurement results.
If data output is not set, only the command response is output.
Setting the Data to Output Automatically after Measurements: p. 169
Measurement result The measurement result is output as the response when data output is set.
The measurement result is not output when data output is not set.
Setting the Data to Output Automatically after Measurements: p. 169
Note
ASME
CR
UR E
Delimiter
CR
M
Delimiter
or
CR
Measurement
result
CR
OK
Delimiter
CR
ER
Delimiter
FQ2-S_CH_comm.book 268 ペー 01年626 木日 前1時4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron FQ2-S Series and is the answer not in the manual?

Omron FQ2-S Series Specifications

General IconGeneral
BrandOmron
ModelFQ2-S Series
CategorySecurity Camera
LanguageEnglish

Related product manuals