Command Control
FQ2-S/CH User’s Manual
for Communications Settings
277
5
Appendices
Commands to Set Status
SCENE or S
Change Scene Number
This command changes the scene number to use.
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
Scene number Specifies the scene number (0 to 31) to change to.
or
SCEN E
Scene number (2 digits max.)
C
R
Delimiter
Space (0x20)
S
Scene number (2 digits max.)
C
R
Delimiter
Space (0x20)
CR
OK
Delimiter
CR
ER
Delimiter
FQ2-S_CH_comm.book 277 ペー 01年626 木日 前1時4