Command Control
342
FQ2-S/CH User’s Manual
for Communications Settings
BKDSAVE
This command saves all setting data (all scene data, system data, calibration group data) for the Sensor to the
SD card inserted in the Touch Finder as a backup file.
The destination for backup data is the following fixed directory on the SD card.
\Sensor name\BKD
<Command format>
<Response format>
When Processing Is Performed Normally
When Processing Is Not Performed Normally
<Parameter Descriptions>
If the specified file name already exists, this existing file will be overwritten.
Do not turn off power to the Vision Sensor until there is a response.
All setting data backup file
name
This command specifies the all setting data backup file name.
The file name extension (.bkd) can be omitted.
BKDSAV E
C
R
All setting data backup file name
Space (0x20)
Important
FQ2-S_CH_comm.book 342 ペー 01年626 木日 前1時4