Command Control
FQ2-S/CH User’s Manual
for Communications Settings
343
5
Appendices
CLBSAVE
This command saves the calibration data with the specified calibration number as a file to the SD card inserted
in the Touch Finder.
The destination for calibration data is the following fixed directory on the SD card.
\Sensor name\CLB
<Command Format>
<Response Format>
When the Command Is Processed Normally
When the Command Is Not Processed Normally
<Parameter Descriptions>
• If the specified file name already exists, this existing file will be overwritten.
• Do not turn off power to the Vision Sensor until there is a response.
CGRSAVE
Saves all calibration data as a file to the SD card inserted in the Touch Finder.
The destination for all calibration data is the following fixed directory on the SD card.
\Sensor name\CGP
<Command Format>
Scene number Specifies the scene number (0 to 31) to be saved.
Calibration data file
name
Specifies the file name when saving.
The file name extension (.clb) can be omitted.
CLBSAV E
Space (0x20)Space (0x20)
C
R
Calibration data file name
Scene number (2 digits max.)
Delimiter
CR
OK
CR
ER
Delimiter
CGRSAV E
C
R
All calibration data file name
Space (0x20)
FQ2-S_CH_comm.book 343 ページ 2014年6月26日 木曜日 午前11時47分