Command Control
FQ2-S/CH User’s Manual
for Communications Settings
373
5
Appendices
z Clearing Measurement Values: 280F 00102010
This command clears the measurement values.
Command Format
Response Format
End Codes
z Clear Errors: 280F 00102040
This command clears the error output status (error output and error indicator).
Format
Response Format
End Codes
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F 00102010
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 00102010
End code (hex) Meaning
0000 Command execution ended normally.
FFFF Command execution ended in an error.
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F 00102040
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 00102040
End code (hex) Meaning
0000 Command execution ended normally.
FFFF Command execution ended in an error.
FQ2-S_CH_comm.book 373 ページ 2014年6月26日 木曜日 午前11時47分