Command Control
428
FQ2-S/CH User’s Manual
for Communications Settings
Save Model Dictionary Data: 280F 0070C000
Saves the specified number of model dictionary data as a file to the SD card inserted in the Touch Finder.
The destination for model dictionary data is the following fixed directory on the SD card.
\Sensor name\DIC
Format
Response Format
End Codes
Parameter Descriptions
If the specified file name already exists, this existing file will be overwritten.
Do not turn off power to the Vision Sensor until there is a response.
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Model dictio-
nary number to
be saved
(4 bytes)
Model dictionary
data file name
(4 to 64 bytes)
28 0F 0070C000 2 digits max. 64 characters
max.
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 0070C000
End code (hex) Description
0000 Command execution ended normally.
FFFF Command execution ended in an error.
Model dictionary number Specifies the scene number (0 to 31) to be saved.
Model dictionary data file
name
Specifies the file name when saving.
The file name extension (.dic) can be omitted.
Important
FQ2-S_CH_comm.book 428 ペー 01年626 木日 前1時4