Command Control
430
FQ2-S/CH User’s Manual
for Communications Settings
Save Latest Input Image Data: 280F 00704020
Saves the latest input image to the SD card inserted in the Touch Finder as ifz data.
The destination for image data is the following fixed directory on the SD card.
\Sensor name\CAPTURE\Number
*
*Number is a five digit number starting from 00000. The images are saved in increments of 100 images for each number, and when there
are over 100 images, the directory with the next number is created.
Format
Response Format
End Codes
Parameter Descriptions
If the specified file name already exists, this existing file will be overwritten.
Do not turn off power to the Vision Sensor until there is a response.
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Image data file name
(4 to 64 bytes)
28 0F 00704020 64 characters max.
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28 0F End code 00704020
End code (hex) Description
0000 Command execution ended normally.
FFFF Command execution ended in an error.
Image data file name Specifies the image data file name to save.