2
Downloading a project
Right-click the project name in the
Solution Explorer pane on the
upper right of the IDE screen, and
select Build and Download All
Programs to run the build and
download.
* The transferred project is not yet
saved to the Controller at this
stage.
If you turn OFF the power to the
Controller, the transferred project
will be discarded.
3
Make sure that there are no errors
in the Output Window.
* If the transfer fails, check details
of the error in the Output Window.
If the error is a program error, you
must review the program.
If the error is related to EtherCAT
settings, return to 6.4 EtherCAT
Communications Setup and check
whether there are any incorrect
settings.
4
The program starts running when
it has been downloaded
successfully.
Make sure that EtherCAT
communications are in the OP
state, and that the motor rotates.
* If the motor does not rotate,
check that the ECAT[0].Enable
value is 1 in the Terminal tab page
or Watch Window.
If the value is 0, run the following
command from the Terminal tab
page.
enable plc 1

Other manuals for Omron G5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron G5 Series and is the answer not in the manual?

Omron G5 Series Specifications

General IconGeneral
FeedbackIncremental Encoder, Absolute Encoder
CommunicationEtherCAT
Safety FunctionSTO (Safe Torque Off)
Protection FunctionsOvervoltage, Undervoltage, Overcurrent
Vibration Resistance4.9 m/s² (10 to 55 Hz)

Related product manuals