2 Standard Functions
2 - 40
NX-series Safety Control Unit Instructions Reference Manual (Z931)
DINT_TO_INT
This function converts a DINT variable to an INT variable.
If you omit an input or output parameter, a building error will occur.
This function converts DINT data In to INT data Out.
To convert INT data to DINT data, refer to INT_TO_DINT.
• The input condition depends on whether the output is safety data or standard data. If the condition is
not met, a building error will occur.
• If you set a safety data type variable for the output terminal, set a safety data type variable for the
input terminal as well.
• If you set a standard data type variable for the output terminal, you can set either a safety data type
variable or a standard data type variable for the input terminal.
• If the input value is not DINT#−32768 to DINT#32767, a cast error will occur and the program will
stop.
Instruction Name FB/FUN Graphic expression
DINT_TO_INT Convert DINT to
INT
FUN
Variables
Name I/O Description Valid range Default
In Data to con-
vert
Input Data to con-
vert
DINT#−32768 to 32767 DINT#0
Out Conversion
result
Output Conversion
result
INT#−32768 to 32767 INT#0
Boolean Bit strings Integers Durations
BOOL
SAFEBOOL
BYTE
SAFEBYTE
WORD
SAFEWORD
DWORD
SAFEDWORD
INT
SAFEINT
DINT
SAFEDINT
TIME
SAFETIME
In OK OK
Out OK OK
Function
Additional Information
Precautions for Correct Use