4-67
Setting Explanation
Setting Explanation
0 Notch filter 1 function not used.
1 Notch filter 1 used in torque commands. (Set the frequency using Pn409, and set the Q
value using Pn40A).
Set whether or not to use notch filter 1 for internal torque commands (current loop commands).
Use the notch filter to prevent mechanical resonance. This function can be used to raise the speed
loop gain and to shorten positioning time.
Note 1. With W
-series AC Servo Drivers, two notch filters can be set: notch filter 1 and notch filter 2.
Note 2. For details on notch filters, refer to 4-8-7 Notch Filter (Position, Speed, Internally-set Speed
Control).
Pn408.1 Torque command setting –– Not used.
Setting
range
--- Unit --- Default
setting
0 Restart
power?
No
Note Do not change the setting.
Pn408.2 Torque command setting –– Notch filter 2 function selection
Setting
range
0, 1 Unit --- Default
setting
0 Restart
power?
No
Setting Explanation
Setting Explanation
0 Notch filter 2 function not used.
1 Notch filter 2 used in torque commands. (Set the frequency using Pn40b, and set the Q
value in Pn40C.)
Set whether or not to use notch filter 2 for internal torque commands (current loop commands).
Use the notch filter to prevent mechanical resonance. This function can be used to increase the speed
loop gain and to shorten positioning time.
Note 1. With W
-series AC Servo Drivers, two notch filters can be set: notch filter 1 and notch filter 2.
Note 2. For details on notch filters, refer to 4-8-7 Notch Filter (Position, Speed, Internally-set Speed
Control.
Note 3. This new parameter is supported by Servo Drivers with software version “r.0037.”
Pn408.3 Torque command setting –– Not used.
Setting
range
--- Unit --- Default
setting
0 Restart
power?
No
Note Do not change the setting.
Pn409 Notch filter 1 frequency
Setting
range
50 to 2000 Unit Hz Default
setting
2000 Restart
power?
No
Enabled when Pn408.0 (notch filter 1 function selection) is set to 1.
Sets the mechanical resonance frequency.
Operation Chapter 4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OMNUC R88D-WT15HF and is the answer not in the manual?

Omron OMNUC R88D-WT15HF Specifications

General IconGeneral
BrandOmron
ModelOMNUC R88D-WT15HF
CategoryServo Drives
LanguageEnglish

Related product manuals