*1. Functions are changed by using Control Mode Selection (Pn02). It operates as the Deviation Counter Reset Input
(ECRST), at the default setting 2: Advanced Position Control or 0: High-response Position Control. When you set 1:
Internally Set Speed Control, it operates as the Internally Set Speed Selection 2 (VSEL2).
*2. Functions are changed by using Zero Speed Designation/Torque Limit Switch (Pn06).
● At the default setting 1: Zero Speed Designation Input (VZERO) Enabled, it operates as the Zero Speed Designation
(VZERO) when you set 1: Internally Set Speed Control at Control Mode Selection (Pn02).
It operates as the Gain Switch (GSEL), at the default setting 2: Advanced Position Control or 0: High-response
Position Control of Control Mode Selection (Pn02).
● When you set 0: Disabled, the Zero Speed Designation (VZERO) function is disabled; however, at the default setting
2: Advanced Position Control or 0: High-response Position Control of Control Mode Selection (Pn02), it operates as
the Gain Switch (GSEL).
● When you set 2: Torque Limit Switch Input (TLSEL) Enabled, it will always operate as the Torque Limit Switch Input
(TLSEL) regardless of the setting of Control Mode Selection (Pn02).
*3. Functions are changed by using Control Mode Selection (Pn02). It operates as the Electronic Gear Switch (GESEL),
at the default setting 2: Advanced Position Control or 0: High-response Position Control. When you set 1: Internally Set
Speed Control, it operates as the Internally Set Speed Selection 1 (VSEL1).
[Electrical specifications]
● In both the SS2 and the G5 series
• 12 to 24-VDC power supply input: 12 VDC-5% to 24 VDC+5%
• Control input: ON level: 10 V or more, OFF level: 3 V or less (input current: 10 mA max.)