3-24
3-7 Parameter List
3
Operation
Multi-step speed, Jogging
A038 Jogging frequency 0.00/Starting frequency to 9.99 6.00 Yes Hz
4-18
A039
Jogging stop
selection
00: Free running on jogging stop/
Disabled in operation
01: Deceleration stop on jogging stop/
Disabled in operation
02: DC injection braking on jogging stop/
Disabled in operation
03: Free running on jogging stop/
Enabled in operation
04: Deceleration stop on jogging stop/
Enabled in operation
05: DC injection braking on jogging stop/
Enabled in operation
00 No
V/f characteristics
A041
Torque boost
selection
00: Manual torque boost
01: Automatic torque boost
00
No
4-19
A241
* 2nd torque boost
selection
00
A042
Manual torque boost
voltage
0.0 to 20.0
1.0
Yes %A242
* 2nd manual torque
boost voltage
1.0
A342
* 3rd manual torque
boost voltage
1.0
A043
Manual torque boost
frequency
0.0 to 50.0
5.0
Yes %A243
* 2nd manual torque
boost frequency
5.0
A343
* 3rd manual torque
boost frequency
5.0
A044
V/f characteristics
selection
00: Constant torque characteristics (VC)
01: Special reduced torque characteristics
(special VP)
02: Free V/f characteristics
03: Sensorless vector control (SLV)
04: 0-Hz sensorless vector control
05: Sensor vector control (V2)
00
No 4-21
A244
* 2nd V/f
characteristics
selection
00: Constant torque characteristics (VC)
01: Special reduced torque characteristics
(special VP)
02: Free V/f characteristics
03: Sensorless vector control (SLV)
04: 0-Hz sensorless vector control
00
A344
* 3rd V/f
characteristics
selection
00: Constant torque characteristics (VC)
01: Special reduced torque characteristics
(special VP)
00
A045 Output voltage gain 20. to 100. 100. Yes % 4-24
Parameter
No.
Function name Monitor or data range
Default
setting
Changes
during
operation
Unit Page
* 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001
to C008.