3-39
Param-
eter
No.
Regis-
ter No.
(Hex)
Name Description Set-
ting
range
Default
setting
Chan-
ges
during
opera-
tion
Memo
n176 01B0
(See
note.)
Parameter
copy and
verify func-
tion selection
Selects the function to read, copy,
and verify the parameter between
the memory of the Inverter and that
of the Digital Operator.
rdy: Ready to accept the next com-
mand.
rEd: Reads the Inverter parameter.
Cpy:Copies the parameter to the
Inverter.
vFy: Verifies the Inverter parameter.
vA: Checks the Inverter capacity
display.
Sno:Checks the software number.
rdy to
Sno
rdy No
n177 01B1
(See
note.)
Parameter
read prohibit
selection
Select the copy-prohibit function.
Set this parameter to store the data
in the EEPROM of the Digital Oper-
ator.
0: Read prohibited for Inverter
parameters (data cannot be
stored in EEPROM).
1: Read possible for Inverter param-
eters (data can be stored in
EEPROM).
0, 1 0 No
n178 01B2 Fault log
Used to display the four most recent
fault recorded.
Display
Note The most recent fault is indi-
cated by “1.”
Note This parameter is monitored
only.
Fault
generation
item
--- --- ---
n179 01B3 Software
number
Used to display the software num-
ber of the Inverter for OMRON’s
control reference use.
Note This parameter is monitored
only.
--- --- ---
Note Parameters for register numbers 01B0 and 01B1 cannot be written from RS–422/485 communications or
the Option Unit. These parameters are read–only.
List of Parameters Chapter 3