3.2.188 MHELICALSP
/i
3.2.189 MOD
/i
3.2.190 MOTION_ERROR
/i
Type Axis command
Syntax MHELICAL(end1, end2, centre1, centre2, direction, distance3 [,mode]))
Description Forced speed version of the MHELICAL command. When the command is
loaded into the move buffer the FORCE_SPEED and ENDMOVE_SPEED is
copied into the buffer with the move.
This move type has exactly the same parameters as the non-forced speed
version MHELICAL.
Arguments end1
Position on BASE axis to finish at.
end2
Position on next axis in BASE array to finish at.
centre1
Position on BASE axis about which to move.
centre2
Position on next axis in BASE array about which to move.
direction
The direction is a software switch which determines whether the arc is
interpolated in a clockwise or anti- clockwise direction. The parameter is
set to 0 or 1. See MOVECIRC.
distance3
The distance to move on the third axis in the BASE array axis in user
units.
mode
0 = Interpolate the third axis with the main two axis when calculating path
speed (true helical path).
1 = Interpolate only the first two axes for path speed, but move the third
axis in coordination with the other 2 axes (circular path with following
third axis).
Example In a series of buffered moves using the look ahead buffer with MERGE=ON a
helical move is required where the incoming vector speed is 40 units/second
and the finishing vector speed is 20 units/second.
FORCE_SPEED=40
ENDMOVE_SPEED=20
MHELICALSP(100,100,0,100,1,100)
See also MHELICAL, FORCE_SPEED, ENDMOVE_SPEED
Type Mathematical function
Syntax expression1 MOD expression2
Description The MOD function returns the expression2 modulus of expression1. This
function will take the integer part of any non-integer input.
Arguments expression1
Any valid BASIC expression.
expression2
Any valid BASIC expression.
Example >> PRINT 122 MOD 13
5.0000
See also N/A