EasyManuals Logo

Omron TJ2-MC64 - PROGRAMMING User Manual

Omron TJ2-MC64 - PROGRAMMING
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #319 background imageLoading...
Page #319 background image
Examples and tips
PROGRAMMING MANUAL 313
Revision 1.0
'if no alarm, notify RUN=$99 or BaseBlock=$BB
ELSEIF(DRIVE_STATUS AND 8) THEN
VR(servo_alarm+i*2)=$99
ELSE
VR(servo_alarm+i*2)=$bb
ENDIF
ENDIF
NEXT i
sys_error=SYSTEM_ERROR
RETURN
'--------------------------------------------------------
stop_all:
'In this example, if the application program is stopped
'suddenly all the movements are cancelled and all the axes
'are set to BaseBlock. Modify this section if you require
'a different STOP procedure
STOP "APPLICATION"
WDOG=0
FOR i= 0 TO max_axis
BASE(i)
IF MARK=0 THEN REGIST(-1)
AXIS_ENABLE=0
SERVO=0
CANCEL(1) 'Cancel NTYPE
WA(1)
CANCEL(1) 'Cancel possible program buffer
NEXT i
RAPIDSTOP 'Cancel MTYPE
RETURN