3-1SectionData Carrier Motion and Command Conditions
17
4. Once processing is completed, the ID Controller sends a response to the
host computer indicating that processing indicated by the auto command
has been completed.
Functions
Read
Write
Read
Auto
Read
Polling Auto Read
Write
Auto W
rite
Polling Auto W
rite
3-1-5 Polling Function
The following describes command processing when two R/W Heads are con-
nected
to one ID Controller
. In the case of normal auto commands, the ID Con
-
troller
does not return a response until the DC comes close to the specified
R/W
Head. This means that until the response is sent,
the
communications path with
the host computer remains in the busy status, and the host computer cannot
send commands specifying the ID Controller’s other R/W Head. However, the
polling auto command enables the ID Controller to return the response when
requested
by the
host computer
. Thus, the busy condition on the communication

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C