3-4SectionCommand Types and Responses
42
Subcommand Format
Header
P W C/E 1/2 FCS
For 1 to 1 procedure
Polling
auto
write
R/W Head no.
Specifies cancel or inquiry of polling auto processing results
C: Processing result inquiry
E: Cancel
R/W Head no.
P W C/E 1/2
@ Unit No.
FCS
For 1 to N procedure
Polling
auto
write
Specifies cancel or inquiry of polling auto processing results
C: Processing result inquiry
E: Cancel
Header
00 to 15
Subcommand Response Format
PW0 0
For 1 to 1 procedure
Header
Polling
auto
write
00:
At normal end
74: DC not close (after second pass)
75:
Polling auto processing canceled (before communications
processing with DC)
76:
Polling auto processing canceled (the DC approaches, and
processing is canceled during communications processing
with the DC and after completion of processing)
End code (see page
48)
PW0 0
@ Unit No.
FCS
For 1 to N procedure
Header
Polling
auto
write
00:
At normal end
74: DC not close (after second pass)
75:
Polling auto processing canceled (before communications
processing with DC)
76:
Polling auto processing canceled (the DC approaches, and
processing is canceled during communications processing
with the DC and after completion of processing)
End code (see page
48)
00 to 15