3-4SectionCommand Types and Responses
43
3-4-7 Auto Command Processing Cancel (AA)
When in the response waiting condition, while auto command (auto read and
auto
write) processing is being executed, it is possible to cancel this and
restore
the command waiting condition.
Command Format
AA
Header
For 1 to 1 procedure
AA
@ Unit No.
FCS
Header
For 1 to N procedure
00
to 15
Response Format
AAXX
Header
For 1 to 1 procedure
End
code (see page
48)
14:
Auto-command processing has not been executed.
75:
Auto command processing has been cancelled.(DC
has not arrived.)
76:
Processing is suspended and canceled during execu
-
tion of auto command(auto write:some of DC data may
be rewritten)
AAXX
@ Unit No.
FCS
For 1 to N procedure
Header
End
code (see page
48)
00 to 15

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C

Related product manuals