3-4SectionCommand Types and Responses
44
3-4-8 Management Data Check (MD C/K)
This command makes it possible to write or collate the CRC code in a check
block that the user designates. The CRC code is calculated using the formula
X
16
+ X
12
+ X
5
+ 1 (refer to
3-2-5 DC Memory Check Function
).
1 to 1 Procedure
Command Format
MDC/K1/2XXXXXX*s
Processing
specification
(C for collation and K for calculation)
R/W
Head No.
designation
Start
address number
Check
block byte number
in HEX
(hexadecimal)
code
[03H, 04H, ..., 00H (256 bytes)]
Response Format
MD 0 0 *s
End
code
00: Normal response (for calculation processing time only)
75: Normal data (for collation processing time only)
76: W
arning code (for collation processing time only)
1 to N Procedure
Command Format
MDC/K1/2XXXXXX
@ Unit No.
FCS
Processing
speed
(C for collation and K for calculation)
R/W
Head No.
designation
Start
address number
Check
block byte number
in HEX
(hexadecimal)
code
(03H, 04H, ..., 00H (256 bytes) )
00 to 15
Response Format
MD 0 0
End
code
00: Normal response (for calculation processing time only)
75: Normal data (for collation processing time only)
76: W
arning code (for collation processing time only)
FCS@ Unit No.
00 to 15
Note The
number of check
block bytes required is the bytes of the check code calcula
-
tion
area plus two bytes. Refer to
3-2-5 DC Memory Check Function
for details.

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C

Related product manuals