EasyManuals Logo

Omron V600 Series Operation Manual

Omron V600 Series
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
3-4SectionCommand Types and Responses
47
Note After the ID Controller receives the abort command, it requires more than
100 ms before it can accept the next command.
3-4-12 Undefined Command Response (IC)
This
is the response returned when the command header cannot be decoded.
Response Format
IC
Header
For 1 to 1 procedure
IC
@ Unit No.
FCS
Header
For 1 to N procedure
00
to 15
3-4-13 Error Response
When
an error occurs during communications with the host computer or during
down
communications, the end code is used to indicate the nature of the error
.
Response Format
XXXX
Header
For 1 to 1 procedure
End
code (see
3-4-14 End Code List
)
(same header as the received command)
XXXX
@ Unit No.
FCS
Header
For 1 to N procedure
(same
header as the received command)
End code(see
3-4-14 End Code List
)
00 to 15

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C