3-4SectionCommand Types and Responses
46
3-4-10 Test Command (TS)
The
test message sent from the host computer is returned without change. The
test
command is used for such purposes as test communications with the host
computer.
Command Format
TSXXX X
For 1 to 1 procedure
1
frame – 266 characters max.
Header Test message
.......
TSXXX X
@ Unit No.
FCS
.......
Test message
Header
For 1 to N procedure
1
frame – 271 characters max.
00 to 15
Response Format
TSXXX X
For 1 to 1 procedure
Header Test
message
.......
For 1 to N procedure
TSXXX X
@ Unit No.
FCS
.......
Test
message
Header
00 to 15
3-4-11 Abort Command (XZ)
If
a problem results in the response not being returning during communications
with
the host computer or during local communications, the abort command can
be
used to restore the ID Controller to the command waiting condition. There is
no response to the abort command.
Command Format
XZ
@ Unit No.
XZ
Header
FCS
Header
For 1 to N procedureFor 1 to 1 procedure
00
to 15

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C