Appendix D
Conformity to Standards
UL (Underwriters’ Laboratories Inc.)
u UL3101
File No. E41515
Listing Mark
CSA (Canadian Standard Association)
C CSA1010.1
File No. LR46463
Listing Mark
EC Directives
We
hereby declare that the following products are in conformity with the requirements of the EC Directives listed
below:
Identification System
V600-CA1A/2A-V2 ID Controllers
V600-Hjj-j Read/Write Heads
V600-Djjj-j Data Carriers
No. of Directive: 89/336/EEC
Title of Directive: Electromagnetic Compatibility
No. of Directive: 73/23/EEC
Title of Directive: Low Voltage Safety
The above referenced products conform to the following standards:
Electromagnetic Compatibility
EMI (Electromagnetic Interference)
Radiated EN50081-2: 1994 / EN55011: 1991
EMS (Electromagnetic Susceptibility)
Electrostatic Discharge EN50082-2: 1995 / EN61000-4-2: 1995
RF Electromagnetic Field EN50082-2: 1995 / ENV50140: 1994
RF Common Mode EN50082-2: 1995 / ENV50141: 1994
Electrical Fast Transient Burst EN50082-2: 1995 / EN61000-4-4: 1995
Power-Frequency Magnetic Field EN50082-2: 1995 / EN61000-4-8: 1993
Electrical Safety
EN61010-1: 1993
IEC1010-1: 1990 / A1: 1992 / A2: 1995

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)