Appendix DConformity to Standards
114
Technical Data
Intended Environment: Industrial
1. Type designation: V600-CA1A/2A-V2
2. Host interface: CA1A-V2: RS-232C
CA2A-V2: RS-422
3. Number of Read/Write Heads connectable: 2 channels
4. Rated power supply voltage: 100 to 240 VAC, 50/60 Hz
5. Acceptable power supply voltage: 85 to 264 VAC
6. Power consumption: 35 VA max.
7. Dielectric strength: 1,500
V
AC, between live parts and protective grounding conductor
3,700
V
AC, between primary and secondary circuits
8. Ambient air temperature: Operating –10° to 55°C
Storage –25° to 65°C
9. IP degree (IEC60529): IP30 (for inner-panel installation)
10. Pollution degree: 2 (controlled environment)
11. Electromagnetic Compatibility (EMC)
a) Field Withstandability: 10 V/m
b) RF Common Mode: 10 V
c) Electrostatic Discharge Withstandability: 4 kV (Contact)
8 kV (Air)
d) Fast Transient Withstandability: 2 kV (DC power)
1 kV (Signal line)
e) Radiated Emission: Class A, Group 1
Model Legend
• ID Controllers
V600-CA1A/2A-V2-j
I II III IV
I – V600: Inductive Identification System
II
– CA1A/2A:
Two Read/Write Heads connectable
-CA1A: Serial interface (RS-232C)
-CA2A: Serial interface (RS-422)
– AC power supply model
III – V2: Version 2
IV –
j
: Blank – Standard model
Suffix(es) – For marketing purposes