4-5SectionOperation Test (TEST)
71
4-5-4 Test Auto Write
One
byte of data is written repeatedly to any memory area
defined by specified
start
and end addresses from the DC while it is in motion. The step number of the
send data can be set to any value in the range 1 to FF (256 bytes maximum),
enabling a total communications test checking relationships between installa-
tion positions, speeds, and other parameters.
Operation Procedure This example shows the procedure for writing FF into locations 10 to 20.
a
_
dXX
4
Job
specification
(head no. and page no)
ADRS
1 0
a
_
dXX
a10dXX
a20dXX
a20dFF
2 0
DATA
F F
TEST 14
TEST
TAW
(2)
(1)
(3)
(4)
(5)
ADRS
RESET
(Cancel
operation by pressing )
RESET
TAW dFF
Test auto write
display
Data
(6)
When
operation is OK
1, 2, 3...
1. Specify the start address.
2. Specify the end address.
3. Specify the data.
4. When the TEST Key is pressed, the test menu is shown on the display.

Other manuals for Omron V600 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V600 Series and is the answer not in the manual?

Omron V600 Series Specifications

General IconGeneral
Operating Frequency13.56 MHz
Supported StandardsISO 15693, ISO 18000-3
Read RangeUp to 70 mm (depending on tag and environment)
Power Supply24 VDC ±10%
Operating Temperature-10 to 55°C (with no icing or condensation)
Humidity35% to 85% (non-condensing)
Communication InterfaceRS-232C

Related product manuals