51
RFID System
User's Manual
SECTION 4
Write Protection
SECTION 4
Functions
Start Address Is Higher Than End Address
The memory area between the start address and the last RF Tag address, as well as the area between
0004 hex and the end address will be write-protected.
■ Disabling Write Protection
Disabling Write Protection for Part of the RF Tags
Set the uppermost bit of 0000 hex to 0.
Disabling All Write Protection for the Whole RFID system
Set the Write Protection Enable Bit to 1 in the FL Remote ID.
Caution When Using Write Protection
The write protect function is a FL Remote ID function. It cannot be used with Reader/Writers manufactured by other
companies.
Address Bit Upper digits Lower digits
0000 hex
1
0000001
81
0001 hex
00100000
20
0002 hex
00000000
00
0003 hex
00010101
15
0000 hex
0004 hex
03E7 hex
0015 hex
0120 hex
Last address
Start address
Write-protected area
Write-protected area