SECTION 5
Detailed Command Settings
SECTION 5
Communications
Detailed Command Settings
The FL Remote ID commands are listed in the following tables.
DATA READ
Master Unit to FL Remote ID
FL Remote ID to Master Unit
Master Unit to FL Remote ID Settings Example
Example: Reading 2 Bytes of Data from Address 120 hex.
Signal Bit length Value Description
CMD 4 0001
B Data read
LEN 4 0001
B Reads 1 byte.
0010
B Reads 2 bytes.
0100
B Reads 3 bytes.
1000
B Reads 4 bytes.
Other Command error
ADDR 16 0000 to FFFF hex Read start address
Signal Bit length Value Description
NORMAL 1 0 or 1 Set to 1 when operation is ended normally.
ERROR 1 0 or 1 The corresponding bit is set to 1 if the command ends in an error.
ERR_SUB * 1 0 or 1 The corresponding bit is set to 1 if RF Tag communications end in an error. The
details of the error are also given.
ID 32 --- Read data
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Bit
CIO
+0
0000001100100001
CIO
+1
CIO
+2
CIO
+3
*****00000100100
Change according to the setting.
DATA READ 2 bytes
Address 120
Fixed
Fixed
Fixed
0111100000010010
0000000010101011