30
Section 2
2.4 IDR/W head: Model V700-HMD11-1
V700-L21
User's Manual
Section 2
Unit Specifications
2.4 IDR/W head: Model V700-HMD11-1
2.4.1 Names and functions of various components/specifications
● Antenna section
This section reads or writes data from or into an ID tag.
● I/F connector
This interface connector supplies power to IDR/W head, and permits data transmission with an
upstream controller.
● Status indicators
■ General specifications
* Be sure to ground the sheet metal that accepts the IDR/W head by class D earth work (grounding
resistance of 100 Ω or less, diameter of grounding conductor of 1.6 mm or greater).
Green Remains lit during data transaction with an ID tag.
Red Lights if data transaction with an ID tag has failed to complete normally.
Characteristic Specification Comment
Supply voltage 5 VDC±5% Supplied from the I/F connector
Current consumption 250 mA max. When 5 VDC is input: approx. 4 A with rush current
Dimensions 40 ×
53 × 23 mm Except for cable
Cable length 1 m (dia. 6 mm) Can be extended to 4 m in conjunction with Model V700-L11
Protection class IP67 (per IEC 60529)
IP67G (per JEM 1030)
The connector is not resistant to water or oil.
Operating ambient temperature −10 to +55°C No freezing
Operating ambient humidity 25 to 85%RH No dew condensation
Storage ambient temperature −25 to +65°C No freezing
Storage ambient humidity 25 to 95%RH No dew condensation
Mounting system Screwed down at two points
with M4.
Capable of mounting to sheet metal*
Communication area
I/F cable
Antenna section
Status indicators
located on side
late
I/F connector
1m