31
V700-L21
User's Manual
Section 2
2.4 IDR/W head: Model V700-HMD11-1
Section 2
Unit Specifications
2.4.2 Interface specifications (same as with Model V700-HMD13 )
<Connection with link unit>
The IDR/W head can be directly connected to the ID connection port on the link unit. When considering
extending the cable, use the cable whose configuration is specified below. Limit the whole cable length
to 4 m.
* For the 5 V/0 V power line, use a cable whose conductor size is AWG22 or greater.
• Recommended cable:OTSC-8PVB-2 No. 22AWG (Onamba)
• Recommended connector: <IDRWH side> socket-Model XM2D-0901 (OMRON),
hood-Model XM2S-0911 (OMRON),
lock-Model XM2Z-0001 (OMRON)
<Link unit side> plug-Model XM2A-0901 (OMRON),
hood-Model XM2S-0911(OMRON)
Characteristic Specification
Connector specification 9-pin D-SUB connector plug, with M2.6 lock screws
Communication standard RS-232C
(Pin arrangement)
Pin No. Signal name Symbol Direction Comment
1
2 Send data SD Input
3 Receive data RD Output
4 Request send RS Input
5 Clear to send CS Output Normally ON
6 +5 V input 5V Input 5 VDC±5%
7 0 V input 0V Input Internally connected to SG
8
9 Signal ground SG − Internally connected to 0V
Link unit
D-SUB
9-pin
plug
M2.6
Symbol Pin No. Pin No. Symbol
IDRWH
D-SUB
9-pin
socket
M2.6
nut
11
SD 2 2 SD
RD 3 3 RD
RS 4 4 RS
CS 5 5 CS
5V 6 6 5V
0V 7 7 0V
88
SG
9
9SG
Wrong wiring connection can lead to a malfunction of the equipment. Be fully sure of the correct
wiring connections.
1
9
*