47
V700-L21
User's Manual
Section 4
4.4 Message specifications
Section 4
SECS Protocol Specifications
4.4 Message specifications
(1) Message list
S F Direction Name per SECS II
1 0 S,HE Abort transaction
1 1 S,HE,reply On line acknowledge request
1 2 S,HE On line data
9 0 S,HE Abort transaction
9 1 S,HE Unrecognized device ID
9 3 S,HE Unrecognized stream type
9 5 S,HE Unrecognized function type
9 7 S,HE Illegal data
9 9 S,HE Transaction timer timeout
9 11 S,HE Data too long
18 0 S,HE Abort transaction
18 1 S,HE,reply Read attribute request
18 2 S,HE Read attribute data
18 3 S,HE,reply Write attribute request
18 4 S,HE Write attribute acknowledge
18 5 S,HE,reply Read request
18 6 S,HE Read data
18 7 S,HE,reply Write data request
18 8 S,HE Write data acknowledge
18 9 S,HE,reply Read ID request
18 10 S,HE Read ID data
18 11 S,HE,reply Write ID request
18 12 S,HE Write ID acknowledge
18 13 S,HE,reply Subsystem command request
18 14 S,HE Subsystem command acknowledge