46
Section 4
4.3 Support attributes
V700-L21
User's Manual
Section 4
SECS Protocol Specifications
(2) Reader/Writer head attribute definitions
Attribute name Description Access Requested Form
Fundamental
Head Status Current state RO Y 20
"IDLE"
"BUSY"
"NOOP"
Head ID Head number 1-31 RO Y
(multi)
20
"01"-"31"
* "00" represents the CIDRW itself, and must
not be used.
Optional
Cycles Number of read and
write operations per-
formed
RO N 54 (4-byte unsigned integer)
* Not yet supported with this CIDRW system
Head Condition Current maintenance
status
RO N 20
NO: no alarms
NM: Needs maintenance.
RW: Read/write fault
RT: Read/write rate fault
* Not yet supported with this CIDRW system
NP: No power or connection error
(Head Date Installed) Date this head was
installed
RO N 20 "YYYYMMDD"
* Not yet supported with this CIDRW system
(Head Maintenance Data) Supplier dependent RO N 20
* Not yet supported with this CIDRW system

Table of Contents