EasyManua.ls Logo

Omron V700-D23P41 - Spacing for Installing IDRW Heads

Omron V700-D23P41
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
70
Section 6
6.2 Performance Data Based on Operating Conditions (information only)
V700-L21
User's Manual
Section 6
Reference
6.2.2 Spacing for installing IDRW heads
When two or more IDRW heads are connected to one CIDRW controller unit, there is no limitation on the
spacing of antenna sections since all the IDRW heads do not handle a command simultaneously.
If IDRW heads in an individual CIDRW system are installed in close vicinity, and when these IDRW heads are
simultaneously processing a command, mutual interference can occur across the IDRW heads, possibly
leading to total inability of communication or loss in effective communication distance despite presence of
tags. To avoid such a problem, be sure to install the antenna sections at the intervals specified below.
Model V700-HMD13
1000 mm or greater
Model V700-HMD11-1
Side-by-side configuration
410 mm or greater
Face-to-face configuration
460 mm or greater
1000 mm or greater 1000 mm or greater
410 mm or greater 410 mm or greater
460 mm or greater

Table of Contents

Related product manuals