(1) CIDRW attributes
Attribute name Description Access Requested Form
Fundamental
Configuration Number of heads RO Y 20 "00"-"31"
Number of heads connected at the time of
powering ON the CIDRW system (automatic
recognition)
Alarm Status Current CIDRW substate
of ALARM STATUS
RO Y 20
0=NO ALARMS
1=ALARMS
Operational Status Current CIDRW substate
of OPERATIONAL
RO Y 20
"IDLE"
"BUSY"
"MANT"
Software Revision Level Revision (version) of
software
RO Y 20 6byte
"VVV.RR"
* VVV= version, RR=revision
Optional
Date Installed Date where the sub-
system was installed
RW N 20 8byte
Factory setting is " " (spaces)
Device Type Identifies subsystem as
either CIDR or CIDRW.
RO N 20 5byte
"CIDRW"
Hardware Revision Level Revision (version) of
hardware
RO N 20 6byte
"VVV.RR"
* VVV=version, RR=revision
Maintenance Data Supplier dependent RW N 20 80byte
Factory setting is " " (spaces)
Manufacturer The name or ID of the
manufacturer
RO N 20 17byte
"OMRON Corporation"
Model Number The manufacturer's
model designation
RO N 20 6byte
"L21 "
(SerialNumber) Subsystem serial num-
ber assigned by the
manufacturer
RO N 20 max. 20 bytes