59
V700-L21
User's Manual
Section 4
4.4 Message specifications
Section 4
SECS Protocol Specifications
S18,F13 Subsystem command request (Reset) S,HE,reply
L,3
1.<TARGETID> Fixed at "00"
2.<SSCMD> "Reset"
3.L,0
S18,F14 Subsystem command acknowledge (Reset) S,HE
L,3
1.<TARGETID> "00"
2.<SSACK>
3.L,0
• When the specified target is invalid:
s=0, SSACK = CE (communications error)
• When SSCMD is invalid:
SSACK = CE (communications error)