6 Programming Features
125
Factory Settings
• Frequency Agree Signal (setting=2)
16 Reverse run Closed during reverse run. -
17 Speed search Closed when Inverter conducts a
speed search.
-
18 Data output from com-
munications
Operates multi-function output termi-
nal independently from Inverter opera-
tion
(by MEMOBUS communication)
141
19 PID feedback loss Closed during PID feedback loss. 163
20 Frequency reference
loss
Closed during frequency reference
loss.
183
21 Inverter overheat alert Closed during Inverter overheat alert. 111
22 monitor motor selection closed during select motor 2 -
No. Terminal Factory Setting
n057 MA, MB 0 (fault)
n058 P1 1 (operating)
n059 P2 2 (frequency agree)
Setting Name Description Ref.
page
Detection Width
±2 Hz
Release Width
±4 Hz
Output Frequency
Frequency Agree Signal