EasyManuals Logo

Omron VARISPEED V7 User Manual

Omron VARISPEED V7
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
156
Register number 0900H is used only for write-in. If this register is read-
out, a register number error (error code: 02H) occurs.
n170
Setting
Description
0 Accepts the Enter Command (constant saving) while the
Inverter is stopped.
1 Always accepts the Enter Command (constant storing).
The new constant becomes valid even if the Enter Com-
mand is not input. If the Enter Command is not used, how-
ever, the value returns to the stored value when the power
supply is turned ON again.