EasyManua.ls Logo

Omron ZEN - Write Time Data

Omron ZEN
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.3 Detailed Description of the Services
29
Example
Command
[STX]000000701
Response
[STX]00000070105112823302006
Year to Seconds
The time data expressed in two digits of BCD data is converted to two
ASCII characters.
Response Code
Normal Completion
Error Occurred
Write Time Data
This service reads ZEN time data.
Note: Refer to ntlp:3-2 Setting the Date and Time in the ZEN Program-
mable Relay Operation Manual (Cat. No. Z211) for information on
setting the date and time.
0 5 1 1 2 8 2 3 3 0 2 0 0 6
Saturday (6)
20 seconds
28th
November
2005
30 minutes
23rd hour
Response
code
Name Description
0000 Normal completion No errors were found.
Response
code
Name Description
1001 Command too long The command is too long.
2203 Operation error Unit error (Memory error occurred,
or unused command was sent.)

Other manuals for Omron ZEN

Related product manuals