SECTION 2 CompoWay/F Communications Protocol
32
Response Code
Normal Completion
Error Occurred
Operation Command
This service switches between RUN and STOP.
Service Request PDU
Service Response PDU
Command Code and Related Information
Response Code
Normal Completion
Operation Commands and Precautions
Response
code
Name Description
0000 Normal completion No errors were found.
Response
code
Name Description
1001 Command too long The command is too long.
2203 Operation error Unit error (Memory error occurred,
or unused command was sent.)
MRC SRC
3005
2222
00
Com-
mand
code
Related
informa-
tion
MRC SRC
3005
22 4
Response
code
Command
code
Command content Related information
00 RUN/STOP 00: Switch to RUN
01: Switch to STOP
Response
code
Name Description
0000 Normal completion No errors were found.
Response
code
Error name Cause
1001 Command too long The command is too long.
1002 Command too short The command is too short.