Through-beam Sensor Heads: FUN Mode Functions Section 3-8
103
Examples: Monitor Focus 2
Examples: Monitor Focus 3, Enabling Differentiation
4
4
Sensor display value
(mm)
Sensor display value
(mm)
Sensor display value
(mm)
0
5.0
For these settings:
For these settings:
4
4
4
Linear output voltage
Linear output voltage
Linear output
voltage
(V)
(V)
(V)
3
2
4
0 1.25 3.75 5.0
0 0.625 3.75 5.0
1.25 mm: 4 V
3.75 mm: 4 V
0.625 mm: 3 V
3.75 mm: 2 V
20
20
18
12
0 2.5 3.75 5.0
Linear output
current
(mA)
Linear output
current
(mA)
4
4
Sensor display value
(mm)
Sensor display value
(mm)
0 2.5
5.0
For this setting:
12
3.75 mm: 18 mA