Thermocode 2 Printer manual Version 2.04 January 2011 45
Error Codes
Note-:
45
Error
Number
Error Message Reason Corrective Measures
The first
error shown with in the Mini Terminal is the fault. Any other error faults shown
on the display, maybe generated because of this fault shown
86
Format has no
image
The Format has not been
generated for the Image
Memory. When other Faults
have occurred.
Rectify the faults within the Format.
87
Line with no
network number
Format sent to the wrong
network number.
Check the Network numbers are correct.
88
Line with
unwanted
network number
Network number selected in
Codesoft. Printer has no
Network number set.
Printer settings, then Advanced. Uncheck the
“Network” box. Then click OK.
89
Burn file corrupt
Bad date written in the Burn
File before being compiled,
or corrupted on send.
Check & correct the Burn file
90
Burn file to long
Incorrect burn file design. Check & correct the burn file.
91
Burn duty too
high
1. The Burn duty in the
Format has been set too
high.
2. The Burn duty in Set
Parameters is too high.
3. The Burn duty is close to
or set on the upper limit
and the room or head
temperature has raised.
1. Reduce the Burn duty within the Format and
resend to the Printer. Or Change with in the
Mini Terminal.
1. 2 & 3. Reduce the Burn duty within
Set Parameters.
92
H table overrun
Internal software error. Report, with format to Open Date UK
93
R table overrun
Internal software error. Report, with format to Open Date UK
94
V table overrun
Internal software error. Report, with format to Open Date UK
95
Bad case
Internal software error. Report, with format to Open Date UK
96
Can’t write
parameter
update
Internal software error.
Try INEW, then report, with format to Open Date
UK
97
Can’t read
parameter
update
Internal software error.
Try INEW, then report, with format to Open Date
UK
98
Bad file copy
Internal software error.
Try INEW, then report, with format to Open Date
UK
99
Can’t open temp
FMS
Internal software error.
Try INEW, then report, with format to Open Date
UK
100
Can’t open
parameter file
Internal software error.
Try INEW, then report, with format to Open Date
UK
101
Can’t open
format file
Internal software error.
Try INEW, then report, with format to Open Date
UK
102
Get Character
fail
Internal software error.
Try INEW, then report, with format to Open Date
UK
103
CM_ALLOCATE
fail
Internal software error.
Try INEW, then report, with format to Open Date
UK
104
FM_ALLOCATE
fail
Internal software error.
Try INEW, then report, with format to Open Date
UK
105
Write to read
only store
Internal software error.
Try INEW, then report, with format to Open Date
UK
106
Read only store
missing
Internal software error.
Try INEW. Try reloading .HEX file, report, with
format to Open Date UK
107
ASY_STAT bad
Internal software error. Report, with format to Open Date UK
108
Print On Line
Printer waiting a print signal. (No error)
109
Loading Format
Format being loaded to the
image memory.
(No error)
110
Creating Image
Image being created within
the image memory.
(No error)
111
Printing
Only seen when printing
large formats at low speed.
(No error)