Thermocode 2 Printer manual Version 2.04 January 2011 47
Error Codes
Error
Number
Error Message Reason Corrective Measures
47
139
Print Before
image update
The Printer Image memory
has not updated the variable
information sent to the
printer, usually from a data
base (UPMODE 3)
Ensure the update is sequenced correctly.
140
Day/Month offset
wrong
Day offset entered with a
month offset
Correct the formats design. Remove the day offset
if a month offset is required. You cannot use both
types of offset at once.
141
Comm output
timeout
Printer port timed out.
Clear the error. Then resend the data if required.
If the Printer has locked up, Reboot the Printer.
142
Printer Locked
Variable CFRPT2 has been
set to 2.
You cannot send any formats or fonts to printer
when locked. Clear the error, unlock the Printer
then resend the format or font.
143
IP_SMALL_BUFF
TCP/IP
Internal error
Try reloading the Firmware.
Contact Open Date UK
144
LOCKED
Incorrect use of CFRPT2 Correct the way you using of CFRPT2
145
Serial Line
overflow
Using the “
0Y”
command
more than once. Returns
variable data to a computer,
using UPMOD 4 & UPMOD 5
Correct the format design and re send too the
printer.
146
Variable type
unknown
Trying to create an un-
recognizable variable
(Not a counter or date)
Recreate the variable the correct way.
Recognized by our Printers
147
Var File
Trying to use a file type
variable and cannot open the
File with the data
Correct the variable file and resend to the Printer
148
Comtrig invalid
Invalid field entry in the
variable SYSCOMTRIG
Correct the data entered in the SYSCOMTRIG field.
149
Comtrig loop too
small
The distance between the
formats is too small.
Increase the distance between the Prints in
SYSCOMTRIG
150
Trggers /image
don’t match
SYSCOMTRIG is in correct,
doesn’t match the formats
Correct the SYSCOMTRIG or the number of
formats required for printing.
151
Using COMTRIG
without SYSILEN
No Value set in SYSILEN
Send the length of the largest image to be printed.
The value is in millimetres.
152
Multi Image
select invalid
Valid Image memories are
W0X, W1X, W2X. X being
Image number
Two or more image memory numbers are the
same.
Correct the Image memory number. See document
Multi Printing for Continuous & Intermittent Printers.
153
No image
selected with
SYSILEN
SYSILEN has no image
memory address.
The SYSILEN has not been allocated an image
memory address. (ILEN ,00,01,02 etc)
154
COHDEL to big
COHDEL is set to large in
relation the Print Height &
Pressure
Reduce COHDEL. Then clear the error
Max value is dependent on Print head height. This
is measured in steps.
155
No Press
confirmed
No pressure confirmed.
Internal software error.
Pressure not seen in the internal software loop
when starting to print. To indicate the difference
between a pressure or pressure sensor fault.
156
Bad PCX
PCX graphic error
Change or modify the graphic and resend to the
printer.
157
Counter field
CINIT
Counter fields not recognised
after installing new firmware.
CINIT the printer then reload the fonts and formats
158
Speed to slow
Variable type
MCPSLOW
is
set to 1
The parent machine speed is the same as or slower
then value set in
MCSPEED
Note-:
The first
error shown with in the Mini Terminal is the fault. Any other error faults shown on
the display, maybe generated because of this fault shown.