10. Environmental Specifications
10.1. Temperature
Operating Temperature : - 0 ~ 40 °C
Storage Temperature : -40 ~ 70
°C
<Conditions>
Barcode : 0.33 mm UPC/EAN specified in Section 9.1
Distance : 65 mm from the front edge of the scanner
Angle
: α = 0°, β =+15°, γ = 0°
Reading test : Read at intervals of 300 ms
10.2. Humidity
Operating Humidity : 5 ~ 90% RH (no condensation, no frost)
Storage Humidity : 5 ~ 90% RH (no condensation, no frost)
<Conditions>
Barcode : 0.33 mm UPC/EAN specified in Section 9.1
Distance : 65 mm from the front edge of the scanner
Angle
: α = 0°, β =+15°, γ = 0°
10.3. Ambient Light Immunity
Scanning performance is guaranteed when the illuminance on a barcode surface is between zero
and the following values:
Incandescent Light : 10,000 lx
Fluorescent Light : 10,000 lx
Sunlight : 100,000 lx
<Conditions>
Barcode : 0.33 mm UPCEAN specified in Section 9.1
Distance : 130 mm from the front edge of the scanner
Angle
: α = 0°, β =+15°, γ = 0°
Figure 17: Ambient Light Immunity
Note: Scanning performance is guaranteed as far as the direct ambient light or specular reflection from the
illumination LED does not enter the light receiving section of the M-10.