EasyManua.ls Logo

Oracle StorageTek T10000

Oracle StorageTek T10000
310 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mode Sense Command
118 T10000: Interface Reference Manual August 2016
LBP_W
Logical Blocks Protected during
0 = Protection Information is not included with the data
transferred when writing.
1 = Protection Information is included with the data transferred
when writing.
Note – If the Logical Block Protection Method field is set to zero,
the LBP_W bit is set to zero.
LBP_R:
Logical Blocks Protected during
Read
0= Protection Information is not included with the data transferred
when reading.
1 = Protection Information is included with the data transferred
when reading.
Note: If the Logical Block Protection Method field is set to zero,
the LBP_R bit is set to zero.
RBDP:
Recover Buffered Data Protected
0 = Protection Information is not included with the data
transferred by the Recover Buffered Data command.
1 = Protection information is included with the data transferred by
the Recover Buffered Data command. (This bit is Ignored).
Notes:
If the Logical Block Protection Method field is set to zero, the
RBDP bit is set to zero.
If the Logical Block Protection Method field is set to a non-zero
then this bit is ignored.
T10 PI Exponent: This field determines the size of each user data field (in bytes)
when T10 PI protected mode is selected.
0h = 1 bytes
1h=2
2h=4
3h=8
4h=16
5h=32
6h=64
7h = 128
8h = 256
9h = 512
Ah = 1,024
Bh = 2,048
Ch = 4,096
Dh = 8,192
Eh = 16,384
Fh = 32,768
T10000D only supports Exponent values 9h through Fh.