Mode Sense Command
118 T10000: Interface Reference Manual August 2016
LBP_W
Logical Blocks Protected during
0 = Protection Information is not included with the data
transferred when writing.
1 = Protection Information is included with the data transferred
when writing.
Note – If the Logical Block Protection Method field is set to zero,
the LBP_W bit is set to zero.
LBP_R:
Logical Blocks Protected during
Read
0= Protection Information is not included with the data transferred
when reading.
1 = Protection Information is included with the data transferred
when reading.
Note: If the Logical Block Protection Method field is set to zero,
the LBP_R bit is set to zero.
RBDP:
Recover Buffered Data Protected
0 = Protection Information is not included with the data
transferred by the Recover Buffered Data command.
1 = Protection information is included with the data transferred by
the Recover Buffered Data command. (This bit is Ignored).
Notes:
If the Logical Block Protection Method field is set to zero, the
RBDP bit is set to zero.
If the Logical Block Protection Method field is set to a non-zero
then this bit is ignored.
T10 PI Exponent: This field determines the size of each user data field (in bytes)
when T10 PI protected mode is selected.
0h = 1 bytes
1h=2
2h=4
3h=8
4h=16
5h=32
6h=64
7h = 128
8h = 256
9h = 512
Ah = 1,024
Bh = 2,048
Ch = 4,096
Dh = 8,192
Eh = 16,384
Fh = 32,768
T10000D only supports Exponent values 9h through Fh.
Parameters Value