EasyManua.ls Logo

Oracle StorageTek T10000

Oracle StorageTek T10000
310 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Unit Ready Command
228 T10000: Interface Reference Manual August 2016
Test Unit Ready Command
The Test Unit Ready command checks if a device is loaded and ready to receive a
command that accesses the media, such as Read or Write commands.
Notes:
Good status is returned if the tape drive is loaded and ready.
Check Condition status with a sense key of Not Ready is returned if the tape
drive is not loaded.
Busy status is returned if a Rewind, Erase, Load/Unload, or Locate command
with the immediate bit set was previously issued and the tape drive has not
completed the command.
TABLE 3-172 Test Unit Ready Command
Byte
Bit
76543210
0 Operation Code (00h)
1
thru
4
(MSB)
Reserved
(LSB)
5 Control Byte

Table of Contents

Other manuals for Oracle StorageTek T10000

Related product manuals