When sharpening electrodes, be sure to remove them from the stylus first. Use the included
diamond wheel in a rotary tool to reshape the tips. Be sure to follow all safety instructions
provided by the rotary tool manufacturer. When grinding down the tips, attempt to create a 15°
angle to the tip as shown below. A sharp tip welds better in much the same way that a sharp pencil
writes better. However, grinding a very small flat surface on the tip of the electrode tip will improve
the number of welds between tip sharpening.
Cleaning Guidelines
Work pieces: e included fiberglass brush can be used to clean off weld debris and
discoloration from weld areas. e bristles are extended and retracted by twisting the top.
General Cleaning Guidelines: Be sure to only perform cleaning on the Orion when it is switched
off and unplugged. Never use abrasive cleaning implements on any part of the Orion.
Do not blow compressed air into any part of the Orion as this may damage the internal
components. Never use any chemicals besides mild detergents on any part of the Orion.
Always clean the Orion’s parts indirectly by moistening or spraying a soft cloth first, and then
use only the cloth to perform the cleaning.
Stylus and Hand Attachments: If discoloration appears at the end of the stylus or hand
attachment, it can be wiped off using a moistened cloth.
Cables and Cords: Detach cables and cords from the Orion and wipe them off using a
moistened cloth.
Orion’s Case and LCD Screen: Wipe gently with a moistened cloth being careful not to let any
moisture into the air vents.