25
An openable door (with detection switches) is provided in the middle
of the door so it will be easy to access the welding chamber. When
middle door is closed machine works normally, when the door is
opened instead, EVO X stops, sending WARNING N°15 message and
protecting the room from possible LASER emission.
Once door is closed, WARNING state will be restored after one
second and operator can go back to normal work condition.
Machine must be START again after the WARNING appears.