EasyManua.ls Logo

OROTIG EVO X - Filter Maintenance; Checking Rear and Internal Filters; Air Vents and Grid Cleaning

OROTIG EVO X
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operator Manual
Chapter:
Maintenance
27
Checking the filters
Checking the rear filter
There is a removable metal mesh filter in the rear lower part of the machine, which
must be cleaned every 3 months. To do this, loosen the clamping screws, slide the
grid out, blow the filter and vacuum the internal seat.
WARNING! Leave at least 10 cm around the machine to promote correct ventilation and sanitisation by the UV lights.
Checking the internal filter
Loosen the 4 red pawls shown in the photo and remove the grid.
Clean by blowing with compressed air and vacuum the internal part where the fumes extractor fan is
found.
Failure to clean this filter can compromise operations and damage the equipment.
Checking the air vents and grid
Periodically vacuum the lateral air vents on the hood
and the cooling fan grid.
WARNING! Lack of maintenance can compromise operation of the equipment and damage it.