4. Open connection (4) and fill
with coolant fluid of sufficient
grade temperature-wise until
it exits from connection (1).
5. Undo the hose on the seawater
pump (3) and drain the
seawater.
An alternative solution is to run the
outboard with the water-intake point
in the front of the lower housing
lowered into a coolant fluid mixture
of sufficient grade.
Run the outboard until the entire
sea-water part of the system is filled
with coolant fluid and thus protected
from freezing and corrosion.
Another alternative is to connect
a rubber hose (2) to the seawater
strainer connector (1). Insert
the other end of the hose into a
container filled with cooling fluid
mixture. Run the outboard until
the entire sea-water part of the
system is filled with coolant fluid and
thus protected from freezing and
corrosion.