68
MAINTENANCE
J1939
SPN
J1939
FMI
Description
521344 2 Control head 0 port lever pot failure
2)
521345 2 Control head 1 port lever pot failure
2)
521360 2 Control head 0 port lever pot mismatch
2)
521361 2 Control head 1 port lever pot mismatch
2)
521440 2 Control head 0 stbd lever pot failure
2)
521441 2 Control head 1 stbd lever pot failure
2)
521456 2 Control head 0 stbd lever pot mismatch
2)
521457 2 Control head 1 stbd lever pot mismatch
2)
521504 13 Control head 0 invalid configuration
1)
521505 13 Control head 1 invalid configuration
1)
521520 13 Control head 0 invalid calibration
1)
521521 13 Control head 1 invalid calibration
1)
521536 31 Control head 0 duplicate instance
1)
521537 31 Control head 1 duplicate instance
1)
521552 31 Control head 0 take command button fault
2)
521553 31 Control head 1 take command button fault
2)
521568 31 Control head 0 sync button fault
2)
521569 31 Control head 1 sync button fault
2)
521584 31 Control head 0 port neutral button fault
2)
521585 31 Control head 1 port neutral button fault
2)
521600 31 Control head 0 stbd neutral button fault
2)
521601 31 Control head 1 stbd neutral button fault
2)
521616 31 Control head 0 multiple controllers selected
1)
521617 31 Control head 1 multiple controllers selected
1)
1)
Calibration possible
2)
Require control replacement or hardware repair
OXE CONTROLS FAULT CODE LIST