55
No. Function name
Changes
during RUN
Setting range Unit
Initial
value
P333
7nd Step Speed
Runtime
○ 0.0 · 0.1 to 6553 0.1[sec] 0.0
P334
8nd Step Speed
Runtime
○ 0.0 · 0.1 to 6553 0.1[sec] 0.0
P335
Winding Mode
Control Selection
○
0: Winding mode control OFF
1: Based on set frequency
2: Based on maximum frequency
- 0
P336
Amplitude in
Winding Mode
○ 0.0 to 100.0 0.1[%] 50.0
P337
Recoil Frequency
Band in Winding
Mode
○ 0.0 to 100.0 0.1[%] 10.0
P338
Winding Mode
Cycle
○ 0.0 to 3600 0.1[sec] 10.0
P339
Rise Time
Coefficient in
Winding Mode
○ 0.0 to 100.0 0.1[%] 50.0
P340
Operation Selection
in Winding Mode
-
0: Normal mode
1: Normal 2-point mode
2: Random swing mode
3: 2-point random swing mode
- 0
P341
Maximum Random
Rise Time
Coefficient
- 0.0 to 100.0 0.1[%] 50.0
P342
Mimimum Random
Rise Time
Coefficient
- 0.0 to 100.0 0.1[%] 50.0
P343
Winding Length
Multiplier
- 0 to 9999 - 1
P344
Winding Stop
Length
- 0 · 1 to 9999,1.000 to 60.00 1[m] 0
P345 PID Target Value ○ 0.0 to 100.0 0.1[%] 0.0
P346 PID Upper Limit ○ 0.0 to 100.0 0.1[%] 100.0
P347 PID Lower Limit ○ 0.0 to 100.0 0.1[%] 0.0
P348 PID Bias Value ○ –100 to 100.0 0.1[%] 0.0
P349
Proportional Gain
[Kp]
○ 0.1 to 1000 - 1.0
P350 Integral Time [Ti] ○ 0.00 to 360.0
0.01[sec]
0.00
P351 Derivative Time [Td] ○ 0.00 to 10.00
0.01[sec]
0.00
P352 Control Cycle [Ts] ○ 0.00 to 60.00
0.01[sec]
0.00
P353
PID Output
Characteristics
-
0: Reverse operation
1: Forward operation
- 0
P354
PID Output Reverse
Selection
-
0: Reverse operation invalid
1: Reverse operation valid
- 0
P355
Sleep Operation
Frequency
○ 0.0 · 0.2 to 400.0 0.1[Hz] 0.0